Sign In | Join Free | My udpf.com
China Henan Yuji Boiler Vessel Manufacturing Co., Ltd. logo
Henan Yuji Boiler Vessel Manufacturing Co., Ltd.
Adhering to Honesty and Foundry Quality
Active Member

6 Years

Home > Coal Fired Hot Water Boiler >

Automatic Coal Fired Hot Water Boiler Draft Fan Cooling Wall Full Combustion

Henan Yuji Boiler Vessel Manufacturing Co., Ltd.
Contact Now

Automatic Coal Fired Hot Water Boiler Draft Fan Cooling Wall Full Combustion

  • 1
  • 2

Brand Name : Yuji

Model Number : Coal Fired Hot Water

Certification : ISO CE

Place of Origin : China (Mainland)

MOQ : 1 set

Price : Negotiable

Supply Ability : 5 Sets per month

Delivery Time : 15 days

Packaging Details : wood packet

Power : 1.4MW

Pressure : 1.0MPa

Outlet Water Temperature : 95℃

Efficiency : 83%

Design Fuel : Coal

Water Volumn : 3.59m³

Weight : Depends

Color : Customization

Contact Now

Product Discription

SZL Series Double Drum Chain Grate Biomass Water Boiler

SZL series double drum chain grate biomass hot water boiler, boiler host design as double boiler drum longitudinal layout, set steam water separating device in upper boiler drum, set periodic blow-off device in lower boiler drum, there are water cooling wall tubes at left and right side of furnace. Use light chain grate add fuel automatically, the back of furnace is re-burning chamber, convection tubes, the tail of furnace is economizer or air preheater, equip with blower, draft fan for mechanical ventilation, and also equip with slag extractor for slagging automatically. Fuel fall down to chain grate and enter furnace for burning, the flue gas go through furnace, re-burning chamber, convection tubes, economizer or air preheater into tail flue, enter deduster, draft fan and chimney, and finally discharge into atmosphere.


Product Features

1. Installation convenience:

The boiler is generally fast-loading factory, easy to transport and on-site installation, greatly shorten the construction cycle, save installation costs, so that the boiler can be put into production in time.

2. Reliable operation:

Boiler heating surface layout is reasonable, water circulation is smooth, and each heating surface is cooled in time, so as to effectively ensure the safe operation of the boiler.

3. Maintenance and repair convenience:

Boiler drum set up manhole, can enter inspection repair. It is convenient to open the smoke box in front of the boiler, and the personnel can check it easily and clearly, which provides a good condition for correct treatment.

4. Full combustion:

With the secondary air and reasonable furnace design, the fuel can be fully burned and the black smoke can be eliminated.

5. High efficiency grate:

Boiler grate adopts double side ventilation, which is brought naturally to the front end of boiler row by dust cleaning technology, which avoids air leakage, fuel leakage and uneven ventilation, and is easy to operate, and has obvious advantages compared with ordinary grate.

6. Convenient ash cleaning:

Many ash cleaning holes can be set up on the boiler, which can remove ash in time and effectively, avoid the trouble of operation and decrease of thermal efficiency caused by boiler ash accumulation, and ensure the stability of boiler load.

Automatic Coal Fired Hot Water Boiler Draft Fan Cooling Wall Full Combustion

Technical Parameters

Item Unit SZL1.4 SZL2.8 SZL4.2 SZL5.6 SZL7 SZL10.5 SZL14 SZL17.5
Thermal Power MW 1.4 2.8 4.2 5.6 7 10.5 14 17.5
Outlet Pressure MPa 1.0 1.0 1.0 1.0 1.0 1.0/1.25/1.6 1.0/1.25/1.6 1.0/1.25/1.6
Outlet Temperature 95 95 95/115 95/115 95/115 95/115 95/115 95/130
Feed Water Temperature 70 70 70 70 70 70 70 70
Thermal Efficiency / ≥83%
Fuel / Biomass particles
Fuel Consumption Kg/h 348.6 685 938.8 1366.2 1694.6 2583 3410 4272
Heating area m2 81.26 165.26 233 351.2 391 547.6 826 1110
Grate area m2 2.8 6.04 8.64 11.71 13.64 15.33 19.16 26.3
Power consumption Kw 25.3 34 62.4 76.2 87.2 138 206.5 218
water volume m3 3.59 6.67 8.33 8.42 12.7 13.9 15.6 18

Note: the fuel consumption in the table is calculated on the basis of the low calorific value of biomass particles 17084KJ/Kg (4085Kcal/Kg). If the low calorific value of biomass fuel is larger than this value, the corresponding fuel consumption will be more economical than the value in the table.

External and Interface Dimension of SZL Biomass Hot water boiler

Item Unit SZL1.4 SZL2.8 SZL4.2 SZL5.6 SZL7 SZL10.5 SZL14 SZL17.5
Steam Capacity t/h 1.4 2.8 4.2 5.6 7 10.5 14 17.5

Transport Dimension

L mm 5600 7380 6900 7000 2800 8700 11900 10700
W mm 2500 2700 2660 3400 3020 3340 3200 3000
H mm 3500 3740 3500 3700 3500 3570 2360 4000
Maximum Transport Weight / t 24.5 31 30 32.5 34 35 35 36
Outlet Water Valve DN mm 100 125 150 200 200 250 2*200 2*200
Feed Water Valve DN mm 100 125 150 200 200 250 2*200 2*200
Safety Valve Diameter DN mm 1*50 2*40 2*50 2*50 2*50/80 100*80 2*100 2*100
Drain Valve Pipe Diameter DN mm 2*40/50 3*40 40/3*50 4*40 6*40 6*40 8*40 8*40
Chimney Diameter φ mm 350 410 530 720 750 950 1000 1200

Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.

Automatic Coal Fired Hot Water Boiler Draft Fan Cooling Wall Full CombustionAutomatic Coal Fired Hot Water Boiler Draft Fan Cooling Wall Full Combustion


Product Tags:

coal fired water heater

      

coal fired central heating

      
Best Automatic Coal Fired Hot Water Boiler Draft Fan Cooling Wall Full Combustion wholesale

Automatic Coal Fired Hot Water Boiler Draft Fan Cooling Wall Full Combustion Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Henan Yuji Boiler Vessel Manufacturing Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)